Key technical facts
- Coverage
- Consumption varies according to the required film thickness (approx. 1500 g/m² for a thickness of 1 mm).
- Mixing Ratio (by weight)
- A/B (84/16)
- Pot Life (min., 23°C, 100 ml)
- 60-100
- Drying Time (23°C) – Touch dry (hours)
- 8-10
- Drying Time (23°C) – Full Cure (weeks)
- 1
- Mixed Density (g/cm³, 20°C)
- 1,75 ± 0,10
Last updated:
This page has been translated from the product's original information. Please refer to the technical data sheet for binding technical values.
Images

Description
DEMCO EPOX 170 PR/F is a solvent-free, epoxy-based, filled primer. It adheres to the surface it is applied to and increases its impact strength and chemical resistance. It also ensures that subsequent coats and/or fillers broadcast onto it before full cure adhere to the surface. Thanks to its filler content, it can also be used as a scratch coat.
Advantages
- Contains no solvents.
- Easy to apply.
- Thanks to its self-flowing property, it levels itself on the surface to which it is applied.
- Penetrates the capillary pores within the concrete structure.
- Prevents dusting of concrete surfaces and increases the chemical and impact resistance of the concrete.
- Thanks to its filling properties, it is also used as a scratch coat.
Technical Properties
| Number of Components | 2 |
| Mixing Ratio (by weight) | A/B (84/16) |
| Mixed Density (g/cm³, 20°C) (TS EN ISO 2811-1) | 1,75 ± 0,10 |
| Pot Life (min., 23°C, 100 ml) (DIN 16945) | 60-100 |
| Mixed Viscosity (mPas, 25°C) (EN ISO 3219) | 900-1300 |
| Drying Time (23°C) (TS 4317) | |
|---|---|
| Touch dry (hours) | 8-10 |
| Full Cure (weeks) | 1 |
| Thinner | Must not be diluted with thinner. |
Surface Preparation and Application
Surface preparation: Surfaces to be coated must be free of oil, rust, dust and similar contaminants. The surface must be free of moisture, and no loose layer whatsoever may remain. Glossy surfaces must be roughened by shot blasting or scarifying. The prepared concrete surface should be primed, preferably with the solvent-free epoxy impregnation primer DEMCO EPOX 100 PR, so that it is fully impregnated, following the application instructions. Any cracks and holes in the surface must be repaired using epoxy putty.
Mixing: The entire B component should be poured into the A component, and the two components should be mixed for at least 3 minutes until a homogeneous mixture is formed. Mixing at low speed is recommended to prevent air bubbles from forming in the mixture.
Application: DEMCO EPOX 170 PR/F is applied to the prepared and primed surface with a notched trowel. If no filler or quartz broadcast is required on top, the entrapped gases are released with a spiked roller. If filler or quartz is broadcast, the loose quartz is swept off after 24 hours. After the surface has been treated with a scraper or power trowel, DEMCO EPOX 170 PR/F is applied as a scratch coat with the flat side of the trowel. Once it is touch-dry, the desired topcoat is applied.
Application Conditions
- Working area temperature must be 15°C – 30°C.
- The ideal substrate temperature is 15°C – 30°C. The temperature must never be below 10°C.
- For both outdoor and indoor applications, substrate and ambient temperature as well as ambient humidity must be taken into account.
- The relative moisture of the substrate must be below 4% and the ambient humidity below 80%.
- For 24 hours after application, the surface must not be touched and must not come into contact with water.
- A suitable amount of mixture should be prepared during work, and work should continue until the entire mixture has been used.
- When applied at 20 – 25°C, the product reaches full cure at room temperature in 7 days on average.
Coverage
Consumption varies according to the required film thickness (approx. 1500 g/m² for a thickness of 1 mm).
Storage and Shelf Life
At 15 – 25°C, in dry, enclosed storage areas away from direct sunlight, in the unopened original packaging; 1 year.
Packaging
Total Net: 20 kg (A: 16,80 kg / B: 3,20 kg)
Safety Precautions
Avoid contact of the mixture or components with skin and eyes; in case of contact, rinse with plenty of water and seek medical advice. Wear protective gloves, clothing and goggles, and keep the product out of reach of children.
Approvals / Standards
Tested to EN 1504-2 within the scope of CE certification.