Key technical facts
- Coverage
- Without thinning, a dry film thickness of 100 – 150 µm is obtained with a consumption of 0,250 – 0,300 kg/m² in a single coat.
- Mixing Ratio (by weight)
- A/B (25/75)
- Pot Life (min., 23°C, 100 ml)
- 150 – 180
- Drying Time (23°C) – Touch Dry (Hours)
- 8 – 10
- Drying Time (23°C) – Full Cure (Weeks)
- 1
- Mixed Density (g/cm³, 20°C)
- 1,30 ± 0,10
Last updated:
This page has been translated from the product's original information. Please refer to the technical data sheet for binding technical values.
Images

Description
Two-component, water-based epoxy topcoat. Applied to the interior walls of buildings and to all types of floors. Provides very good adhesion to plaster and concrete surfaces.
Advantages
- High mechanical strength.
- Excellent wipeability and cleanability.
- Odorless.
- Environmentally friendly.
- Viscosity can be adjusted by adding water.
- Can be applied as a primer when diluted with water at a ratio of 2/1.
Application Areas
- Interior walls of buildings
- All types of floors
Suitable Substrates
- Plastered surfaces
- Concrete surfaces
Technical Properties
| Number of Components | 2 |
| Mixing Ratio (by weight) | A/B (25/75) |
| Mixed Density (g/cm³, 20°C) (TS EN ISO 2811-1) | 1,30 ± 0,10 |
| Pot Life (min., 23°C, 100 ml) (DIN 16945) | 150 – 180 |
| Mixed Viscosity (mPas, 25°C) (EN ISO 3219) | 300 – 500 |
| Drying Time (23°C) (TS 4317) | |
|---|---|
| Touch Dry (Hours) | 8 – 10 |
| Full Cure (Weeks) | 1 |
| Recoating Interval (at room conditions) | 4 – 5 hours |
| Thinner | Must not be diluted with thinner. |
Surface Preparation and Application
- Surfaces to be coated must be free of oil, rust, dust and similar contaminants.
- The surface to be coated must be free of moisture, and no loose layer whatsoever may remain.
- Glossy surfaces must be roughened by shot blasting or scarifying.
- The prepared concrete surface is primed with Water-Based Epoxy Primer DEMCO EPOX 180 PR/W or with DEMCO EPOX 185 TOP COAT/W diluted with water at a ratio of 2:1.
- Pour all of component B into component A and mix the two components for at least 3 minutes until a homogeneous mixture is obtained. Mixing at low speed is recommended to prevent air bubbles from forming in the mixture.
- After priming, DEMCO EPOX 185 TOP COAT/W is applied by brush, roller or airless spray.
- When applying the primer and topcoat, allow 4 – 5 hours between coats under room conditions.
Application Conditions
- Working area temperature must be 15°C – 30°C.
- The ideal substrate temperature is 15°C – 30°C. The temperature must never be below 10°C.
- For both outdoor and indoor applications, substrate and ambient temperature as well as ambient humidity must be taken into account.
- The relative moisture of the substrate must be below 4% and the ambient humidity below 80%.
- For 24 hours after application, the surface must not be touched or come into contact with water.
- A suitable amount of mixture should be prepared during work, and work should continue until the entire mixture has been used.
- When applied at 20 – 25°C, the product reaches full cure at room temperature in 7 days on average.
Coverage
Without thinning, a dry film thickness of 100 – 150 µm is obtained with a consumption of 0,250 – 0,300 kg/m² in a single coat.
Storage and Shelf Life
At 15 – 25°C in dry, closed warehouses away from direct sunlight, in unopened original packaging; 1 year.
Packaging
Total Net: 20 kg (A: 5,00 kg / B: 15,00 kg)
Safety Precautions
Contact of the mixture or components with skin and eyes must be avoided; in case of contact, rinse with plenty of water and consult a doctor. Protective gloves, clothing and goggles must be worn. Keep out of reach of children.
Approvals / Standards
Tested to EN 1504-2 within the scope of CE certification.